Answer: Please find below a dimensioned drawing of the QED Universal Spade termination used in the AirLoc ABS Standard Spade. QED Standard Spade termination dimensions
Answer: QED Airloc termination requires a specialist tool to carry out the cold weld crimp, these tools are carried by QED dealers, as are the terminations. Your local QED dealer will be able to advise you on the costs involved to carry out the ...
Answer: The QED AirLoc system is NOT a crimp, but a proper "cold weld". It's agreed with that a crimped connection would be the last thing that you would want for a speaker cable which must carry high current although it CAN be more tolerable in a ...
Answer: In the standard Airloc plugs we use an alpha brass with at least 63% pure copper alloyed with zinc for the body and beryllium copper alloy for the spring part. Alpha brass is used because it can be easily worked when cold during the ...
Answer: The Airloc spades are 24k gold plated, and feature a high copper brass body; specifically CZ131 Riveting Brass which is the perfect compromise between ductility and strength.